RDLC5 is a low-power embedded Wi-Fi module that Tuya has developed. It consists of a highly integrated wireless RF chip (RDA5981BM), a few peripherals, an embedded Wi-Fi network protocol stack, and varied library functions.

Product overview

RDLC5 has an embedded low-power ARM-CM4 MCU, 2-MB flash memory, 448-KB static random-access memory (SRAM), and rich peripherals.

RDLC5 is an RTOS platform that integrates all function libraries of the Wi-Fi MAC and TCP/IP protocols. You can develop embedded Wi-Fi products as required.

Features

  • Embedded low-power 32-bit CPU, which can also function as an application processor
  • The clock rate: 160 MHz
  • Working voltage: 3.3 ± 0.3V
  • Peripherals: 3 GPIOs and 1 universal asynchronous receiver/transmitter (UART)
  • Wi-Fi connectivity
    • 802.11 b/g/n
    • Channels 1 to 14 at 2.4 GHz
    • Support WPA/WPA2/WEP/TKIP security modes
    • Up to +17 dBm output power in 802.11b mode
    • Support STA/AP/STA+AP working mode
    • Support SmartConfig and AP network configuration manners for Android and iOS devices
    • Working temperature: -20 to 105℃

Applications

  • Intelligent building
  • Smart household and home appliances
  • Smart socket and light
  • Industrial wireless control
  • Baby monitor
  • Network camera
  • Intelligent bus

Change history

Update Date Updated Content Version after Update
08/20/2019 This is the first release. V1.0.0
09/16/2019 The document upgrades. V2.0.0

Module interfaces

Dimensions and footprint

RDLC5 has two rows of pins with a 2 mm pin spacing.
The RDLC5 dimensions are 8.5 mm±0.35 mm (W)×12.7±0.35 mm (L) ×2.9±0.15 mm (H).
RDLC5 Module Datasheet

Pin definition

Pin Number Symbol I/O Type Function
1 ANT - RF antenna port, which is connected to an external antenna in a soldering manner
2 1 P GND Power supply reference ground
3 22 I/O GPIO_22/Standard PWM interface, which corresponds to GPIO 22 (Pin 34) of IC
4 24 I/O GPIO_24/Standard PWM interface, which corresponds to GPIO 24 (Pin 32) of IC
5 23 I/O GPIO_23/Standard PWM interface, which corresponds to GPIO 23 (Pin 33) of IC
6 VCC P Power supply pin of the module (3.3V)

Note: P indicates power supply pins and I/O indicates input/output pins.

Definitions on test points

Pin Number Symbol I/O Type Function
- TEST I/O Be used for production tests of the module
- TX I/O When the module is powered on and enabled, there is information output from the serial interface, which is used for production and test and programming authorization of the module.
- N I/O Hardware reset pin, active low
- RX I/O When the module is powered on and enabled, there is information output from the serial interface, which is used for production and test and programming authorization of the module.
- IO2 I/O Be used for debugging and displaying internal log information of the module

Note: Test pins are not recommended.

Electrical parameters

Absolute electrical parameters

Parameter Description Minimum value Maximum Value Unit
Ts Storage temperature -20 105
VBAT Power supply voltage 3.0 3.6 V
Static electricity discharge voltage (human body model) TAMB-25℃ - 2 KV
Static electricity discharge voltage (machine model) TAMB-25℃ - 0.5 KV

Normal working conditions

Parameter Description Minimum value Typical Value Maximum Value Unit
Ta Working temperature -20 - 105
VBAT Power supply voltage 3.0 3.3 3.6 V
VIL IO low-level input -0.3 - VCC*0.25 V
VIH IO high-level input VCC*0.75 - VCC V
VOL IO low-level output - - VCC*0.1 V
VOH IO high-level output VCC*0.8 - VCC V
Imax IO drive current - - 12 mA

TX and RX power consumption

Working Status Mode Rate Transmit Power/Receive Average Value Peak Value (Typical Value)) Unit
Transmit 11 b 11Mbps +17 dBm 210 354 mA
Transmit 11 g 54Mbps +14.5 dBm 180 300 mA
Transmit 11 n MCS 7 +13.5 dBm 170 290 mA
Receive 11b 11Mbps Constantly receive 80 100 mA
Receive 11g 54Mbps Constantly receive 80 100 mA
Receive 11n MCS 7 Constantly receive 80 100 mA

Working current

Working Mode Working Status, Ta = 25°C Average Value Maximum Value (Typical Value) Unit
Quick connection network state The module is in the fast network connection state and the Wi-Fi indicator always flashes 70 330 mA
Hotspot network configuration state The module is in the hotspot network configuration state and the Wi-Fi indicator flashes slowly 80 340 mA
Network connection operation state The module is connected to the network and the Wi-Fi indicator is always on 70 220 mA

RF parameters

Basic RF features

Parameter Description
Working frequency 2.412 to 2.484 GHz
Wi-Fi standard IEEE 802.11 b/g/n (channels 1 to 14)
Data transmission rate 11b: 1, 2, 5.5, 11 (Mbps); 11g: 6, 9, 12, 18, 24, 36, 48, 54 (Mbps); 11n: HT20 MCS 0 to 7

TX performance

TX performance

Parameter Minimum Value Typical Value Maximum Value Unit
Average RF output power, 802.11b CCK Mode 11 M - 17 - dBm
Average RF output power, 802.11g OFDM Mode 54 M - 14.5 - dBm
Average RF output power, 802.11n OFDM Mode MCS7 - 13.5 - dBm
Frequency error -10 - 10 ppm

RX performance

RX sensitivity

Parameter Minimum Value Typical Value Maximum Value Unit
PER<8%, RX sensitivity, 802.11b DSSS Mode 11 M - -90 - dBm
PER<10%, RX sensitivity, 802.11g OFDM Mode 54 M - -73 - dBm
PER<10%, RX sensitivity, 802.11n OFDM Mode MCS7 - -70 - dBm

Antenna information

Antenna type

The module uses an external antenna which is soldered on the ANT pad of the module in a soldering manner.
An antenna with a length of 28 mm is recommended.

Antenna interference reduction

To ensure optimal Wi-Fi performance when the Wi-Fi module uses an onboard PCB antenna, it is recommended that the antenna be at least 15 mm away from other metal parts.

Packaging information and production instructions

Mechanical dimensions

RDLC5 Module Datasheet

Side view

RDLC5 Module Datasheet

The schematic diagram of packaging

RDLC5 Module Datasheet

Production instructions

  1. Tuya’s stamp hole package module must be mounted by an SMT machine, and the mounting must be completed within 24 hours after unpacking and programming of the firmware. Otherwise, it must be packaged again under a vacuum. The module must be baked before mounting.

    • SMT equipment
      • Reflow soldering machine
      • Automated optical inspection (AOI) equipment
      • Nozzle with a 6 mm to 8 mm diameter
    • Baking equipment
      • Cabinet oven
      • Anti-static heat-resistant trays
      • Anti-static heat-resistant gloves
  2. Storage conditions for a delivered module are as follows:

    • The moisture-proof bag must be placed in an environment where the temperature is below 30°C and the relative humidity is lower than 70%.
    • The shelf life of a dry-packaged product is 6 months from the date when the product is packaged and sealed.
    • The package contains a humidity indicator card (HIC).
      RDLC5 Module Datasheet
  3. Bake a module based on HIC status as follows when you unpack the module package:

    • If the 30%, 40%, and 50% circles are blue, bake the module for 2 consecutive hours.
    • If the 30% circle is pink, bake the module for 4 consecutive hours.
    • If the 30% and 40% circles are pink, bake the module for 6 consecutive hours.
    • If the 30%, 40%, and 50% circles are pink, bake the module for 12 consecutive hours.
  4. Baking settings:

    • Baking temperature: 125±5°C
    • Alarm temperature: 130°C
    • SMT ready temperature after natural cooling: < 36°C
    • The number of drying times: 1
    • Rebaking condition: The module is not soldered within 12 hours after baking
  5. Do not use SMT to process modules that have been unpacked for more than 3 months, because electroless nickel/immersion gold (ENIG) is used for PCBs and they are seriously oxidized after more than 3 months. SMT is very likely to cause pseudo and missing soldering. Tuya is not liable for such problems and consequences.

  6. Before SMT, take electrostatic discharge (ESD) protective measures.

  7. To reduce the reflow defect rate, draw 10% of the products for visual inspection and AOI before the first mounting to determine proper methods for controlling the oven temperature and attaching and placing components. Draw 5 to 10 modules from subsequent batches each hour for visual inspection and AOI.

Recommended oven temperature curve

Perform straight plugging based on the following reflow oven temperature curve. The highest temperature is 245°C. The reflow temperature curve is shown below:

RDLC5 Module Datasheet

Storage conditions

RDLC5 Module Datasheet

MOQ and packaging information

Product Number MOQ(pcs) Shipping packaging method The number of modules per reel The number of reels per carton
RDLC5 4000 Tape reel 1000 4

Appendix: Statement

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this device.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This device has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses, and can radiate radio frequency energy and, if not installed and used following the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the device and receiver.
  • Connect the device into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Radiation Exposure Statement

This device complies with FCC radiation exposure limits set forth for an uncontrolled rolled environment. This device should be installed and operated with a minimum distance of 20cm between the radiator and your body.

Important Note

This radio module must not be installed to co-locate and operating simultaneously with other radios in the host system except following FCC multi-transmitter product procedures. Additional testing and device authorization may be required to operate simultaneously with other radios.

The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end-user.

The host product manufacturer is responsible for compliance with any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. The final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed.

The end-user manual shall include all required regulatory information/warnings as shown in this manual, including “This product must be installed and operated with a minimum distance of 20 cm between the radiator and user body”.

This device has got an FCC ID: 2ANDL-RDLC5. The end product must be labeled in a visible area with the following: “Contains Transmitter Module FCC ID: 2ANDL-RDLC5”.

This device is intended only for OEM integrators under the following conditions:

The antenna must be installed such that 20cm is maintained between the antenna and users, and the transmitter module may not be co-located with any other transmitter or antenna.

As long as the 2 conditions above are met, further transmitter tests will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed.

Declaration of Conformity European Notice

RDLC5 Module Datasheet

Hereby, Hangzhou Tuya Information Technology Co., Ltd declares that this module product is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU,2011/65/EU. A copy of the Declaration of conformity can be found at https://www.tuya.com.

RDLC5 Module Datasheet

This product must not be disposed of as normal household waste, in accordance with the EU directive for waste electrical and electronic equipment (WEEE-2012/19/EU). Instead, it should be disposed of by returning it to the point of sale, or to a municipal recycling collection point.

The device could be used with a separation distance of 20cm to the human body.