Send a command of setting a leakage alert value to a circuit breaker. On receiving the command, the circuit breaker will set the leakage alert value.
POST: /v1.0/electric-energy/{device_id}/actions/leak-warn-value
Parameter name | Type | IN | Required | Description |
---|---|---|---|---|
device_id | String | uri | true | The ID of a Tuya device. |
Description of body
Parameter name | Type | IN | Required | Description |
---|---|---|---|---|
leak_warn_value | Integer | true | The leakage alert value to trigger an action. Unit: mA. |
Parameter name | Type | Description |
---|---|---|
result | CmdIssueResultResponse | The returned result. |
Description of result
Parameter name | Type | Description |
---|---|---|
sn | String | The ID of a specified command record. |
POST: /v1.0/electric-energy/6ce****/actions/leak-warn-value
{
"leakWarnValue": 10
}
{
"result": {
"sn": "133****"
},
"t": 1561456817168,
"success": true
}
For more information, see error code.