Last Updated on : 2023-09-07 10:23:12download
Parameter | Value |
---|---|
Profile ID | 0x0104 |
Device ID | 0x0402 |
Endpoint | Description |
---|---|
1 | The endpoint used by the current contact sensor. |
Input clusters (server) | Output clusters (client) |
---|---|
Basic (0x0000) | OTA Upgrade (0x0019) |
Power Configuration (0x0001) | / |
IAS Zone (0x0500) | / |
Attributes
ID | Name | Data type (ID) | Range | Default |
---|---|---|---|---|
0x0000 | ZCLVersion | uint8 (0x20) | 0x00 to 0xff | 0x03 |
0x0001 | ApplicationVersion | uint8 (0x20) | 0x00 to 0xff | For example, 0b 01 00 0001 indicates 1.0.1 , that is, 0x41 represents version 1.0.1. This attribute is used for OTA updates. When an OTA update is initiated, the gateway reads the version number of the update and pushes it to the Zigbee device. After the Zigbee device is restarted after the update, the gateway reads the current version to check for the update result. The firmware can only be updated to a higher version. |
0x0002 | StackVersion | uint8 (0x20) | 0x00 to 0xff | 0x02 |
0x0003 | HWVersion | uint8 (0x20) | 0x00 to 0xff | 0x01 |
0x0004 | ManufacturerName | string (0x42) | 0 to 32 bytes | The value of this attribute is 16 bytes in length, consisting of 8-byte prefix and 8-byte PID. 0 to 7 bytes: _TZ3000_ . 8 to 16 bytes: The PID, the unique identifier of the Zigbee product you create on the Tuya IoT Development Platform. This field determines the UI experience and functions of the app. If no specific PID is required, the default one can be used. |
0x0005 | ModelIdentifier | string (0x42) | 0 to 32 bytes | TY0203 |
0x0007 | PowerSource | enum8 (0x30) | 0x00 to 0xff | 0x03 |
0xFFFD | ClusterRevision | uint16 (0x21) | 0x0000 to 0xffff | 0x0001 |
Attributes
ID | Name | Data type (ID) | Range | Default |
---|---|---|---|---|
0x0000 | MainsVoltage | uint16 (0x21) | 0x0000 to 0xffff | 0x03 |
0x0020 | BatteryVoltage | uint8 (0x20) | 24 to 30 (2.4V to 3.0V) | 30 |
0x0021 | BatteryPercentageRemaining | uint8 (0x20) | 0 to 200 (0 to 100%) | 200 |
0xfffd | ClusterRevision | uint16 (0x21) | 0x0000 to 0xffff | 0x0001 |
Attributes
ID | Name | Data type (ID) | Range | Default |
---|---|---|---|---|
0x0000 | Zone State | enum8 (0x30) | 0x00 to 0xff | 0x00 |
0x0001 | Zone Type | enum16 (0x31) | 0x0000 to 0xffff | 0x0015 |
0x0002 | Zone Status | bitmap16 (0x19) | 0x0000 to 0xffff | 0x0000 |
0x0010 | IAS CIE Address | EUI64 (0xF0) | 8 bytes | NULL |
0x0011 | Zone ID | uint8 (0x20) | 0x00 to 0xff | 0x0000 |
0xFFFD | ClusterRevision | uint16 (0x21) | 0x0000 to 0xffff | 0x0001 |
Commands
ID | Name | Direction | Description |
---|---|---|---|
0x00 | Zone Status Change Notification | Server to client | The Zigbee device reports alarms to the gateway. |
0x01 | Zone Enroll Request | Server to client | The Zigbee device requests the Zone ID from the gateway. |
0x00 | Zone Enroll Response | Client to server | The gateway returns the Zone ID to the Zigbee device. |
Attributes
ID | Name | Data type (ID) | Range | Default |
---|---|---|---|---|
0x0000 | UpgradeServerID | EUI64 (0xF0) | / | 0xffffffffffffffff |
0x0001 | FileOffset | uint32 (0x23) | / | 0x00000000 |
0x0002 | CurrentFileVersion | uint32 (0x23) | / | 0x00000040 |
0x0006 | ImageUpgradeStatus | enum8 (0x30) | / | 0x00 |
0x0007 | Manufacturer ID | uint16 (0x21) | / | 0x1002 |
0x0008 | Image Type ID | uint16 (0x21) | / | 0x1602 |
0x0009 | MinimumBlockPeriod | uint16 (0x21) | / | 0x0000 |
0xfffd | ClusterRevision | uint16 (0x21) | 0x0000 to 0xffff | 0x0001 |
Commands
ID | Name | Direction |
---|---|---|
0x00 | Image Notify | Server to client |
0x01 | Query Next Image Request | Client to server |
0x02 | Query Next Image Response | Server to client |
0x03 | Image Block Request | Client to server |
0x05 | Image Block Response | Server to client |
0x06 | Upgrade End Request | Client to server |
0x07 | Upgrade End Response | Server to client |
DPID | DP description | Standard command |
---|---|---|
1 | Contact sensor | Yes |
2 | Battery level | Yes |
4 | Tamper alarm | Yes |
Direction | Cluster ID | Attribute ID | Value |
---|---|---|---|
Server to client | 0x0500 | 0x0002 (ZoneStatus) | Bit0 (alarm1).
|
The sensor reports 1
when the door is opened and reports 0
when the door is closed.
Direction | Cluster ID | Attribute ID | Value |
---|---|---|---|
Server to client | 0x0001 | 0x0020 (BatteryVoltage) | 0x00 to 0xff |
Server to client | 0x0001 | 0x0021 (BatteryPercentageRemaining) | 0x00 to 0xff |
If the reported value of BatteryVoltage
is 30, it indicates 3.0V voltage. If the reported value of BatteryPercentageRemaining
is 180, it indicates a battery level of 90%.
Direction | Cluster ID | Attribute ID | Value |
---|---|---|---|
Server to client | 0x0500 | 0x0002 (ZoneStatus) | Bit2 (tamper).
|
The sensor reports the alarm
status when the sensor detects tampering and reports no alarm
when the alarm is canceled.
For more information, see DP4 Battery level.