Luminance Sensor

Last Updated on : 2023-09-07 10:23:12download

Zigbee basics

The product is developed based on the Zigbee 3.0 standard protocol.

Parameter Value
Profile ID 0x0104
Device ID 0x0106

Endpoint

Endpoint Description
1 The endpoint used by the current luminance sensor.

Supported clusters

Input clusters (server) Output clusters (client)
Basic (0x0000) OTA Upgrade (0x0019)
Power Configuration (0x0001) /
Illuminance Measurement (0x0400) /
IAS Zone (0x0500) /

Supported attributes and commands

Basic cluster

Attributes

ID Name Data type (ID)
Range
Default
0x0000 ZCLVersion uint8 (0x20) 0x00 to 0xff 0x03
0x0001 ApplicationVersion uint8 (0x20) 0x00 to 0xff 0x40
0x40 in hex is 0100 0000 in binary. 0100 0000 represents version 1.0.0, so 0x40 represents 1.0.0.
0x0002 StackVersion uint8 (0x20) 0x00 to 0xff 0x02
0x0003 HWVersion uint8 (0x20) 0x00 to 0xff 0x01
0x0004 ManufacturerName string (0x42) 0 to 32 bytes The value of this attribute is 16 bytes in length, consisting of 8-byte prefix and 8-byte PID.
0 to 7 bytes: TYZB01.
8 to 16 bytes: The PID, the unique identifier of the Zigbee product you create on the Tuya IoT Development Platform, bb1ibvp5 by default. This field determines the UI and feature display on the mobile app. You can use the default PID if you do not require a custom one.
0x0005 ModelIdentifier string (0x42) 0 to 32 bytes TS0222, used for the gateway to identify the device type.
0x0007 PowerSource enum8 (0x30) 0x00 to 0xff 0x03
0xfffd ClusterRevision uint16 (0x21) 0x0000 to 0xffff 0x0001

Power Configuration

Attributes

ID name Data type (ID) Range Default
0x0000 MainsVoltage uint16 (0x21) 0x0000 to 0xffff 0x03
0x0020 BatteryVoltage uint8 (0x20) 24 to 30 (2.4V to 3.0V) 30
0x0021 BatteryPercentageRemaining uint8 (0x20) 0 to 200 (0 to 100%) 200
0xfffd ClusterRevision uint16 (0x21) 0x0000 to 0xffff 0x0001

IAS Zone

Attributes

ID name Data type (ID) Range Default
0x0000 Zone enroll state enum8 (0x21) 0x00 to 0xff 0x00
0x0001 Zone type uint16 (0x21) 0x0000 to 0xffff 0x8001
0x0002 Zone status bitmap16 (0x19) 0x0000 to 0xffff 0x0000
0x0010 IAS CIE address EUI64 (0xF0) 8 bytes NULL
0x0011 Zone ID Int8 (0x20) 0x00 to 0xff 0x0000
0xFFFD Cluster revision uint16 (0x21) 0x0000 to 0xffff 0x0001

Illuminance Measurement

Attributes

ID name Data type (ID) Range Default
0x0000 Measured value uint16 (0x21) 0x0000 to 0xffff 0x00

Over The Air Upgrade

Attributes

ID name Data type (ID) Range Default
0x0000 UpgradeServerID EUI64 (0xF0) / 0xffffffffffffffff
0x0001 FileOffset uint32 (0x23) / 0x00000000
0x0002 CurrentFileVersion uint32 (0x23) / 0x00000040
0x0006 ImageUpgradeStatus enum8 (0x30) / 0x00
0x0007 Manufacturer ID uint16 (0x21) / 0x1002
0x0008 Image Type ID uint16 (0x21) / 0x1602
0x0009 MinimumBlockPeriod uint16 (0x21) / 0x0000
0xfffd ClusterRevision uint16 (0x21) 0x0000 to 0xffff 0x0001

Commands

ID name Direction Description
0x00 Image Notify Server to client /
0x01 Query Next Image Request Client to server /
0x02 Query Next Image Response Server to client /
0x03 Image Block Request Client to server /
0x05 Image Block Response Server to client /
0x06 Upgrade End Request Client to server /
0x07 Upgrade End Response Server to client /

Mapping between DPs and clusters

DPID DP description Standard command
2 Brightness Yes
4 Battery level Yes
5 Tamper alarm Yes

DP2 brightness value

Direction Cluster ID Attribute ID Value
Server to client 0x0400 0x0000: measured value int16

DP4 Battery level

Direction Cluster ID Attribute ID Value
Server to client 0x0001 0x0020 (BatteryVoltage) 0x00 to 0xff
Server to client 0x0001 0x0021 (BatteryPercentageRemaining) 0x00 to 0xff

If the reported value of BatteryVoltage is 30, it indicates 3.0V voltage. If the reported value of BatteryPercentageRemaining is 180, it indicates a battery level of 90%.

DP5 Tamper alarm

Direction Cluster ID Attribute ID Value
Server to client 0x0500 0x0002 (ZoneStatus) Bit2 (tamper).
  • 0: no alarm
  • 1: alarm

Default heartbeat (4 hours, report battery level)

For more information, see DP4 Battery level.