Set Enabling Switch

Last Updated on : 2023-06-20 14:54:08

Send a command of setting an enabling switch to a circuit breaker. On receiving the command, the circuit breaker will set the enabling switch.

API address

POST: /v1.0/electric-energy/{device_id}/actions/hand-enable

Request parameter

Parameter nameTypeINRequiredDescription
device_idStringuritrueThe ID of a Tuya device.

Description of body

Parameter nameTypeINRequiredDescription
hand_enableInteger trueSet the enabling status of a specified switch. Valid values:
  • 0: disable.
  • 1: enable.

Return parameter

Parameter nameTypeDescription
resultCmdIssueResultResponseThe returned result.

Description of result

Parameter nameTypeDescription
snStringThe ID of a specified command record.

Request example

POST: /v1.0/electric-energy/6ce****/actions/hand-enable
{
  "handEnable": 1
}

Return example

{
    "result": {
        "sn": "133****"
    },
    "t": 1561456817168,
    "success": true
}

Error code