Last Updated on : 2024-11-20 02:12:22download
This topic describes how to use a beacon and gateway to perform production tests on Zigbee sockets and power strips with an energy monitoring function.
According to the different ways of device access to the network, Zigbee electrical production tests can be classified into Zigbee gateway tests and Zigbee beacon dongle tests.
It applies to no-code Zigbee energy monitoring sockets and power strips.
Device | Quantity | Note |
---|---|---|
Device under test | 1 | / |
Production test backplane (PCBA) | 1 | / |
Stable isolated power supply | 1 | The adjustable voltage includes 220V and 120V, and the output power can be viewed. |
Load | 1 |
|
Test jig with a voltmeter | 1 | The voltmeter is powered independently with an isolated switch and power supply. |
Zigbee gateway or beacon dongle | 1 | You need to purchase from Tuya. |
PC | 1 | You need to install 32-bit or 64-bit Windows 7 or later version. |
Software | Note |
---|---|
Tuya solution production test platform | Go to the Tuya PMS. For more information about Tuya PMS account application, see Apply Account. |
JSON file | You can get the JSON file from the package downloaded from the Tuya PMS. |
Get the software
After logging in to the Tuya PMS, download the software and drivers in Production Support in the left navigation bar.
Configuration for the installation of production test platform
Configuration | Requirement |
---|---|
Operating system | 32-bit or 64-bit Windows 7 or later version. |
Hard Disk | More than 200 MB of space is required on the system disk. |
Memory | At least 1 GB. |
Processor | Core i5 or later version. |
Runtime library | .Net Framework 4.0 or later version is installed. |
JSON file setup
Normally the JSON file is already configured according to your requirement, and you do not need to modify it by yourself.
If you want to modify, you can open the JSON file with the notepad tool on your PC, and add or delete the test items.
For example, PCBA does not need to be flashed, so you can delete the firmware update item. The deleted content is as follows.
Note: Do not modify at will to avoid test failures.
Note: Pay attention to the heat dissipation of the load to prevent burns.
ON
(switch to the side of the USB port). Power on the device under test.
Power on the gateway and connect it to the PC with a network cable. Wait until the two indicators turn green and start flickering before you start pairing.
Note: Before performing production tests, you need to update the specific firmware of the gateway. You can get help from Tuya staff.
Open the network settings on the PC, and after you complete the Ethernet configuration of the gateway, click OK.
You can configure the IP address and subnet mask as follows. The last number field of the IP address should be smaller than 254.
Log in to the Tuya solution production test platform
Enter the authorization code that you got by applying in the authorization code box and press the Enter button on your PC.
The software will automatically come up with the production information of the device.
In the Mode> Mode Selection box in the lower left corner, select Debug Mode.
Click Import, select and import the JSON file.
Click Test in the top right corner.
In the corresponding line window, click Configure, and enter the parameters in the pop-up TCP link setting window.
Parameter | Description |
---|---|
IP address | Enter 192.168.1.254. |
Port | Enter 12130. |
Delay | It is recommended to enter 200 milliseconds. |
Press and hold the reset button on the device and wait until the indicator starts flickering before you release the button. If the indicator flickers for a few seconds and then turns off, it indicates that the device is paired. At this time, click Run to start the production test.
Note: The devices that do not indicate as expected during the automatic test can be considered faulty devices.
Wait for the production test platform to send an indicator test command and check whether the indicator flickers.
Wait for the production test platform to send a relay test command and check whether the relay flips.
Wait for the production test platform to send a button test command, press all the buttons manually, and check whether the relay flips.
Wait for the production test platform to automatically complete the battery level calibration and return the result of success or failure.