This topic describes the standard instruction set of heating ventilation air conditioning—HVAC (ntq).

Code Name Data type Value constraint
switch Master switch Boolean {}
switch_gate Gate switch Boolean {}
high_limit_temp High-temperature protection parameters Integer {“unit”:“℃”,“min”:500,“max”:950,“scale”:1,“step”:10}
anti_freeze_temp Anti-freeze parameter setting Integer {“unit”:“℃”,“min”:20,“max”:80,“scale”:0,“step”:10}
sewage_interval_time Sewage discharge interval Integer {“unit”:“day”,“min”:0,“max”:300,“scale”:0,“step”:10}
sewage_time Sewage discharge time setting Integer {“unit”:“min”,“min”:50,“max”:300,“scale”:0,“step”:10}
outlet_temp_calibration Outlet water temperature calibration Integer {“unit”:“℃”,“min”:-50,“max”:50,“scale”:0,“step”:10}
inlet_temp_calibration Inlet water temperature calibration Integer {“unit”:“℃”,“min”:-50,“max”:50,“scale”:0,“step”:10}