This topic describes the standard status set of CO2 detectors (co2bj).
Code | Name | Data type | Data type |
---|---|---|---|
muffling | Mute | Boolean | {} |
self_checking | Device self-check | Boolean | {} |
alarm_time | Alarm duration | Integer | {“unit”:“”,“min”:1,“max”:60,“scale”:0,“step”:1} |
alarm_ringtone | Alarm ringtone | Enum | {“range”:[“1”,“2”,“3”,“4”,“5”]} |
alarm_volume | Alarm volume | Enum | {“range”:[“low”,“middle”,“high”,“mute”]} |
alarm_switch | Alarm switch | Boolean | {} |
alarm_bright | Brightness adjustment | Integer | {“unit”:“”,“min”:0,“max”:100,“scale”:0,“step”:1} |
Code | Name | Data type | Data type |
---|---|---|---|
lifecycle | Service life | Boolean | {} |
preheat | Preheating or not | Boolean | {} |
temper_alarm | Tamper alarm | Boolean | {} |
checking_result | Device self-check result | Enum | {“range”:[“checking”,“check_success”,“check_failure”,“others”]} |
co2_value | CO2 detection result | Integer | {“unit”:“”,“min”:0,“max”:1000,“scale”:1,“step”:1} |
co2_state | CO2 detection status value | Enum | {“range”:[“alarm”,“normal”]} |
battery_percentage | Battery capacity percentage | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
battery_value | Battery capacity value | Integer | {“unit”:“”,“min”:0,“max”:30000,“scale”:0,“step”:1} |
battery_state | Battery capacity status | Enum | {“range”:[“low”,“middle”,“high”,“mute”]} |