Last Updated on : 2022-01-13 03:32:35download
This topic describes the standard status set of electric fireplaces (dbl).
Code |
Name |
Type |
Description |
|---|---|---|---|
| bright_value | Flame brightness | Integer | {“min”:10,“max”:1000,“scale”:0,“step”:1} |
| child_lock | Child lock switch | Boolean | {} |
| countdown_set | Countdown | Enum | {“range”:[“cancel”,“1h”,“2h”,“3h”,“4h”,“5h”,“6h”]} |
| eco | ECO mode | Boolean | {} |
| level | Level | Enum | {“range”:[“level_1”,“level_2”,“level_3”,“level_4”, “level_5”]} |
| light | Light | Boolean | {} |
| mode | Mode | Enum | {“range”:[“smart”,“auto”]} |
| power_set | Flame level | Enum | {“range”:[“level_1”,“level_2”,“level_3”,“level_4”, “level_5”]} |
| sound | Sound | Boolean | {} |
| sound_mode | Sound mode | Enum | {“range”:[“sound_1”,“sound_2”,“sound_3”]} |
| switch | Switch | Boolean | {} |
| temp_set | Temperature setting in °C | Integer | {“unit”:“℃”,“min”:0,“max”:40,“scale”:0,“step”:1} |
| temp_set_f | Temperature setting in °F | Integer | {“unit”:“℉”,“min”:32,“max”:104,“scale”:0,“step”:1} |
| temp_unit_convert | Temperature unit conversion | Enum | {“range”:[“c”,“f”]} |
| volume_set | Volume control | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
| work_mode | Light mode | Enum | {“range”:[“light_red”,“light_yellow”,“light_blue”, “light_pink”,“auto”]} |
Code |
Name |
Type |
Description |
|---|---|---|---|
| countdown_left | Remaining time of countdown | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
| temp_current | Current temperature in °C | Integer | {“unit”:“℃”,“min”:-20,“max”:50,“scale”:0,“step”:1} |
| temp_current_f | Current temperature in °F | Integer | {“unit”:“℉”,“min”:-4,“max”:122,“scale”:0,“step”:1} |
| work_state | Work status | Enum | {“range”:[“heating”,“warm”]} |