Standard Status Set

Last Updated on : 2022-01-13 06:20:22download

This topic describes the standard status set of body fat scales (tzc1).

Status to be sent and reported

Code
Name
Data type
Value
channel_change Channel switching Enum {“range”:[“bluetooth”,“wifi”]}
unit_switch Unit conversion Enum {“range”:[“kg”,“lb”,“st”]}
data_report Data sending Raw {}
broadcast_data Broadcast data Raw {}

Status only to be reported

Code
Name
Data type
Value
battery_low Low battery status Boolean {}
body_r Body impedance Integer {“unit”:“Ohm”,“min”:0,“max”:65535,“scale”:0,“step”:1}
data_identification Flag Enum {“range”:[“reserve_1”]}
heart_rate Real-time heart rate Integer {“min”:1,“max”:300,“scale”:0,“step”:1}
lefthand_r Left hand impedance Integer {“unit”:“Ohm”,“min”:0,“max”:65535,“scale”:0,“step”:1}
leftleg_r Left leg impedance Integer {“unit”:“Ohm”,“min”:0,“max”:65535,“scale”:0,“step”:1}
realtime_data Real-time data Integer {“unit”:“kg”,“min”:0,“max”:1800,“scale”:1,“step”:1}
righthand_r Right hand impedance Integer {“unit”:“Ohm”,“min”:0,“max”:65535,“scale”:0,“step”:1}
rightleg_r Right leg impedance Integer {“unit”:“Ohm”,“min”:0,“max”:65535,“scale”:0,“step”:1}
weight Weight Integer {“unit”:“kg”,“min”:0,“max”:1800,“scale”:1,“step”:1}