Standard Status Set

Last Updated on : 2022-02-09 05:12:52download

This topic describes the standard status set of heaters (rs).

Support reporting instructions to the cloud and sending instructions to the device

Code Name Data type Value constraint
countdown_set Countdown Enum {“range”:[“cancel”,“1h”,“2h”,“3h”,“4h”,“5h”,“6h”]}
temp_unit_convert Temperature unit switching Enum {“range”:[“c”,“f”]}
instant_heating Instant heating Boolean {}
water_set Water level setting Integer {“unit”:“L”,“min”:20,“max”:100,“scale”:0,“step”:5}
temp_set Temperature setting Integer {“unit”:“℃”,“min”:20,“max”:60,“scale”:0,“step”:1}
capacity_set Power setting Enum {“range”:[“2000w”,“3000w”,“5000w”]}
switch_microwave Microwave switch Boolean {}
child_lock Child lock switch Boolean {}
night_power Power supply at night Boolean {}
disinfection Disinfection Boolean {}
eco Eco mode (energy-saving mode) Boolean {}
mode Mode Enum {“range”:[“auto”,“manual”,“smart”,“comfortable”,“eco”]}
switch Switch Boolean {}
temp_set_f Temperature setting(Fahrenheit) Integer {“unit”:“℉”,“min”:0,“max”:150,“scale”:0,“step”:1}
timer Timer Raw {}
capacity_expansion Capacity expansion Boolean {}
outage Water outage Boolean {}
smart_change Smart change Boolean {}
cruise_mode Cruise mode Enum {“range”:[“all_day”,“water_control”,“single_cruise”]}
heating_3d 3D fast heating Boolean {}

Support reporting instructions to the cloud only

Code Name Data type Value constraint
countdown_left Remaining time of countdown Integer {“unit”:“min”,“min”:0,“max”:360,“scale”:0,“step”:1}
surplus_water Remaining water quantity Integer {“unit”:“ml”,“min”:0,“max”:5000,“scale”:0,“step”:1}
work_state Working status Enum {“range”:[“heating”,“warm”]}
power_consumption Power consumption Integer {“unit”:“kW·h”,“min”:0,“max”:10000,“scale”:0,“step”:1}
temp_current Current temperature Integer {“unit”:“ºC”,“min”:0,“max”:100,“scale”:0,“step”:1}
temp_current_f Current temperature(Fahrenheit) Integer {“unit”:“”,“min”:0,“max”:100,“scale”:0,“step”:1}
gas_consumption Air consumption Integer {“unit”:“”,“min”:0,“max”:100,“scale”:0,“step”:1}
work_life_1 Magnesium rod life Integer {“min”:0,“max”:100,“scale”:0,“step”:1}
work_life_2 Liner life Integer {“min”:0,“max”:100,“scale”:0,“step”:1}
water_total Water Consumption Integer {“unit”:“L”,“min”:1,“max”:99999,“scale”:0,“step”:1}
fault Fault Bitmap {“label”:[“sys_high_fault”,“sys_low_fault”,“flow_fault”,
“power_fault”,“cooling_fault”,“heating_fault”,
“temp_dif_fault”,“in_temp_fault”,“eff_temp_fault”,
“coil_temp_fault”,“ret_temp_fault”,“news_fault”,
“amb_temp_fault”,“lack_water”,“serious_fault”,
“sensor_fault”,“motor_fault”],“maxlen”:16}