This topic describes the standard status set of electric blankets (dr).
Code | Name | Data type | Data type |
---|---|---|---|
switch | Switch | Boolean | {} |
temp_set | Temperature setting | Integer | {“unit”:“℃”,“min”:10,“max”:45,“scale”:0,“step”:1} |
mode | Mode | Enum | {“range”:[“high”,“middle”,“low”]} |
eco | ECO mode | Boolean | {} |
child_lock | Child lock switch | Boolean | {} |
anion | Anion | Boolean | {} |
light | Light | Boolean | {} |
countdown_set | Countdown | Enum | {“range”:[“cancel”,“1h”,“2h”,“3h”,“4h”,“5h”,“6h”]} |
Code | Name | Data type | Data type |
---|---|---|---|
temp_current | Current temperature | Integer | {“unit”:“℃”,“min”:0,“max”:50,“scale”:0,“step”:1} |
countdown_left | Remaining time of the countdown in minutes | Integer | {“unit”:“min”,“min”:0,“max”:360,“scale”:0,“step”:1} |