This topic describes the standard status set of heaters (qn).
Code | Name | Data type | Value constraint | Description |
---|---|---|---|---|
switch | Switch | Boolean | {} | None |
temp_set | Temperature setting in °C | Integer | {“unit”:“°C”,“min”:0,“max”:50,“scale”:0,“step”:1} | Set the temperature in °C |
mode | Mode | Enum | {“range”:[“smart”,“auto”]} | Set the mode of the heater |
level | Level | Enum | {“range”:[“1”,“2”,“3”]} | Set the temperature level |
mode_eco | ECO mode | Boolean | {} | None |
lock | Child lock | Boolean | {} | None |
shake | Oscillating | Boolean | {} | None |
anion | Anion | Boolean | {} | None |
light | Light | Boolean | {} | None |
countdown | Countdown | Enum | {“range”:[“cancel”,“1”,“2”,“3”,“4”,“5”,“6”]} | Set the countdown time range. Legacy versions only. |
countdown_set | Countdown | Enum | {“range”:[“cancel”,“1h”,“2h”,“3h”,“4h”,“5h”,“6h”]} | Set countdown time in hours |
c_f | Temperature unit switching | Enum | {“range”:[“C”,“F”]} | Legacy version |
temp_unit_convert | Temperature unit switching setting | Enum | {“range”:[“c”,“f”]} | None |
temp_set_f | Temperature setting in °F | Integer | {“unit”:“℉”,“min”:32,“max”:104,“scale”:0,“step”:1} | Set the temperature in °F |
Code | Name | Data type | Value constraint | Description |
---|---|---|---|---|
temp_current | Current temperature in °C | Integer | {“unit”:“°C”,“min”:-20,“max”:50,“scale”:0,“step”:1} | Current temperature in °C |
countdown_left | Remaining time of countdown | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} | Remaining time of countdown in seconds |
work_state | Working status | Enum | {“range”:[“heating”,“warming”]} | None |
work_power | Actual power | Enum | {“unit”:“w”,“min”:0,“max”:5000,“scale”:1,“step”:1} | None |
temp_current_f | Current temperature in °F | Integer | {“unit”:“℉”,“min”:-4,“max”:122,“scale”:0,“step”:1} | Current temperature in °F |
Is this page helpful?
YesFeedbackIs this page helpful?
YesFeedback