Last Updated on : 2022-12-08 06:24:38download
This topic describes the standard status set of switches (kg), sockets (cz), and power strips (pc).
Code | Name | Data type | Value |
---|---|---|---|
switch | Switch | Boolean | {} |
switch_1 | Switch 1 | Boolean | {} |
switch_2 | Switch 2 | Boolean | {} |
switch_3 | Switch 3 | Boolean | {} |
switch_4 | Switch 4 | Boolean | {} |
switch_5 | Switch 5 | Boolean | {} |
switch_6 | Switch 6 | Boolean | {} |
countdown_1 | Countdown of switch 1 | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_2 | Countdown of switch 2 | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_3 | Countdown of switch 3 | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_4 | Countdown of switch 4 | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_5 | Countdown of switch 5 | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_6 | Countdown of switch 6 | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
switch_usb1 | USB1 | Boolean | {} |
switch_usb2 | USB2 | Boolean | {} |
switch_usb3 | USB3 | Boolean | {} |
switch_usb4 | USB4 | Boolean | {} |
switch_usb5 | USB5 | Boolean | {} |
switch_usb6 | USB6 | Boolean | {} |
countdown_usb1 | USB1 countdown | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_usb2 | USB2 countdown | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_usb3 | USB3 countdown | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_usb4 | USB4 countdown | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_usb5 | USB5 countdown | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
countdown_usb6 | USB6 countdown | Integer | {“unit”:“s”,“min”:0,“max”:86400,“scale”:0,“step”:1} |
child_lock | Child lock | Boolean | {} |
relay_status | Power status setting | Enum | {“range”:[“power_on”, "power_off, “last”]} |
light_mode | Indicator light status setting | Enum | {“range”:[“none”,“relay”,“pos”]} |
switch_backlight | Backlight switch | Boolean | {} |
Code | Name | Data type | Value |
---|---|---|---|
cur_current | Actual current | Integer | {“unit”:“mA”,“min”:0,“max”:30000,“scale”:0,“step”:1} |
cur_power | Actual power | Integer | {“unit”:“W”,“min”:0,“max”:50000,“scale”:0,“step”:1} |
cur_voltage | Actual voltage | Integer | {“unit”:“v”,“min”:0,“max”:50000,“scale”:1,“step”:1} |