This topic describes the standard status set of ventilation systems (xfj).
Code | Name | Data type | Value constraint |
---|---|---|---|
switch | Switch | Boolean | {} |
mode | Working mode | Enum | {“range”:[“auto”,“sleep”,“manual”]} |
air_volume | Air volume | Integer | {“unit”:“m3/h”,“min”:0,“max”:1000,“scale”:0,“step”:1} |
loop_mode | Circulation mode | Enum | {“range”:[“auto”,“indoor_loop”,“outdoor_loop”]} |
supply_fan_speed | Air supply speed | Enum | {“range”:[“off”,“low”,“mid”,“high”]} |
exhaust_fan_speed | Air exhausting speed | Enum | {“range”:[“off”,“low”,“mid”,“high”]} |
fresh_air_valve | Fresh air valve | Boolean | {} |
air_exhaust_fan | Exhaust fan | Boolean | {} |
primary_filter_reset | Reset the primary filter | Boolean | {} |
medium_filter_reset | Reset the medium filter | Boolean | {} |
high_filter_reset | Reset the high-efficiency filter | Boolean | {} |
sterilize | Sterilization | Boolean | {} |
bypass_function | Bypass function | Boolean | {} |
heat | Electric auxiliary heating | Boolean | {} |
pm25_set | PM2.5 parameter setting | Integer | {“unit”:“μg/m3”,“min”:1,“max”:999,“scale”:0,“step”:1} |
eco2_set | eCO2 parameter setting | Integer | {“unit”:“ppm”,“min”:1,“max”:1000,“scale”:0,“step”:1} |
temp_set | Temperature setting | Integer | {“unit”:“℃”,“min”:-50,“max”:50,“scale”:0,“step”:1} |
humidity_set | Humidity setting | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
tvoc_set | TVOC parameter setting | Integer | {“unit”:“ppm”,“min”:0,“max”:1000,“scale”:2,“step”:1} |
air_conditioning | air conditioner | Boolean | {} |
backlight | Backlight brightness | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
purify_mode | Purification mode | Enum | {“range”:[“high”,“low”]} |
purification | Purification/dust removal | Boolean | {} |
dehumidifier | Dehumidification | Boolean | {} |
defrost | Defrost | Boolean | {} |
countdown_set | Countdown | Enum | {“range”:[“cancel”,“1h”,“2h”,“3h”,“4h”,“5h”,“6h”]} |
factory_reset | Restore factory defaults | Boolean | {} |
child_lock | Child lock switch | Boolean | {} |
filter_reset | Reset the filter cartridge | Boolean | {} |
fan_speed_enum | Air speed | Enum | {“range”:[“low”,“mid”,“high”,“sleep”]} |
anion | Negative ion | Boolean | {} |
uv_light | UV light | Boolean | {} |
pm10_set | PM10 parameter setting | Integer | {“unit”:“mg/m3”,“min”:0,“max”:999,“scale”:0,“step”:1} |
Code | Name | Data type | Value constraint |
---|---|---|---|
pm10 | PM10 | Integer | {“unit”:“μg/m3”,“min”:0,“max”:999,“scale”:0,“step”:1} |
humidity_outdoor | Outdoor humidity | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
temp_outdoor | Outdoor temperature | Integer | {“unit”:“℃”,“min”:-50,“max”:50,“scale”:0,“step”:1} |
air_quality | Air quality | Enum | {“range”:[“great”,“good”,“mild”,“medium”,“bad”]} |
supply_temp | Air supply temperature | Integer | {“unit”:“℃”,“min”:-50,“max”:50,“scale”:0,“step”:1} |
exhaust_temp | Air exhausting temperature | Integer | {“unit”:“℃”,“min”:-50,“max”:50,“scale”:0,“step”:1} |
supply_air_vol | Air supply volume | Integer | {“min”:0,“max”:1000,“scale”:0,“step”:1} |
exhaust_air_vol | Air exhausting volume | Integer | {“min”:0,“max”:1000,“scale”:0,“step”:1} |
primary_filter_life | The remaining effective time of the primary filter | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
medium_filter_life | The remaining effective time of the medium filter | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
high_filter_life | The remaining effective time of the high-efficiency filter | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
countdown_left | Remaining time of countdown | Integer | {“unit”:“min”,“min”:0,“max”:360,“scale”:0,“step”:1} |
filter_life | Filter life | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
uv_life | UV life | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
temp_indoor | Indoor temperature | Integer | {“unit”:“℃”,“min”:0,“max”:50,“scale”:0,“step”:1} |
humidity_indoor | Indoor humidity | Integer | {“unit”:“%”,“min”:0,“max”:100,“scale”:0,“step”:1} |
tvoc | TVOC | Integer | {“min”:0,“max”:1000,“scale”:0,“step”:1} |
eco2 | eCO2 | Integer | {“min”:0,“max”:1000,“scale”:0,“step”:1} |
pm25 | PM2.5 | Integer | {“min”:0,“max”:999,“scale”:0,“step”:1} |
fault | Fault alarm | Bitmap | {“label”:[“e1”],“type”:“bitmap”,“maxlen”:1} |
hcho_sensor_value | HCHO parameter | Integer | {“unit”:“mg/m3”,“min”:0,“max”:1000,“scale”:3,“step”:1} |