Last Updated on : 2023-08-10 08:42:20download
This topic describes the hardware design issues in product certification.
This topic is a collection of common hardware design issues in the certification of some products. Note that this documentation is for reference only. The detailed information is subject to the certification authorities.
This topic describes the hardware design issues of some reference products.
In this topic, the explanation of some representations are as follows:
Item | Explanation |
---|---|
L | Live wire |
N | Neutral wire |
L&N | Live wire and neutral wire are connected |
For the production compliance part and EMC part, the customer needs to provide a list of key components with relevant certifications.
Note: For special key components, it is best for customers to provide multiple alternative manufacturers.
When the device is powered off, it is required to check whether L and N are at contact risk.
Reference product: a 10A wall switch with a USB port
Executive standard | Condition | Standard |
---|---|---|
GB4943.1-2011 | There are capacitors with a capacity of more than 0.1 µF on L and N. | The discharge time is less than one second. |
Note: The discharge time is 37% of the time it takes for the voltage to drop to the initial value.
Reference product: a 15A American standard socket converter
Executive standard | Condition | Standard |
---|---|---|
UL 60730-1 | There are capacitors with a capacity of more than 0.1 µF on L and N. | Peak voltage does not exceed 34V after one second. |
Reference product: a 10A wall switch with a USB port
Executive standard | Fuse identifier |
---|---|
GB4943.1-2011 | The fuse parameters need to be marked around the fuse of the PCB. |
Reference product: Australian standard 10A socket converter
Executive standard | Fuse identifier |
---|---|
AS / NZS 3105: 2014 + A1: 2017 AS / NZS 3100: 2017 + A1: 2017 | When the fuse is blown, no spark can be generated. |
Reference product: a 10A wall switch with a USB port
Executive standard | Test current (The rated current is 10A) | Test current (The rated current is 16A) | Test time | Terminal temperature rise |
---|---|---|---|---|
GB/T2099.1 | 16A | 22A | 1 hour | 45k |
Note: The test items include the temperature rise between L and N, L and ground wire, and N and ground wire. The temperature rise needs to be within the working temperature range in the datasheet.
Reference product: appliance switch
Executive standard | Test current (The rated current is 10A) | Test time | Terminal temperature rise |
---|---|---|---|
GB/T15092.1 | 10.6A | After the test temperature is stable, run for another hour. | 45k |
Note: The temperature rise needs to be within the working temperature range in the datasheet.
Reference product: a 15A American standard socket converter
Executive standard | Test current (The rated current is 15A) | Test time | Terminal temperature rise |
---|---|---|---|
UL 60730-1 | 15A | After the test temperature is stable, run for another hour. | 25k |
Executive standard | Test current (The rated current is 15A) | Test time | Terminal temperature rise |
---|---|---|---|
UL 498A | 15A | After the test temperature is stable, run for another hour. | 30k |
Note: The temperature rise needs to be within the working temperature range in the datasheet.
Overload test
Executive standard | Test current (The rated current is 15A) | Test time | Limit temperature |
---|---|---|---|
UL 60730-1 | 27A | 1 hour | 125°C |
Reference product: a 10A wall switch with a USB port
Executive standard | Clearance between different live parts | Clearance between the live part and the accessible insulating surface | Clearance between the live part and the ground wire | Clearance between the fuse soldering spots | Clearance between the electrical device and the extra-low voltage device | Clearance between the ground wire and the extra-low voltage device |
---|---|---|---|---|---|---|
GB/T2099.1 GB4943.1-2011 | 3 mm | 3 mm | 3 mm | 1.5 mm | 4.0 mm | 1.5 mm |
Note: The altitude is below 2000m.
Reference product: a 16A wall switch
Executive standard | Clearance between different live parts | Clearance between the live part and the ground wire | Clearance between the live part and the accessible insulating surface |
---|---|---|---|
GB/T2099.3 | 3 mm | 3 mm | 3 mm |
Reference product: appliance switch
Executive standard | Pollution level | Clearance between different live parts | Clearance between the live part and the ground wire | Clearance between the live part and the accessible insulating surface |
---|---|---|---|---|
GB/T15092.1 | 2 | 1.5 mm | 1.5 mm | 1.5 mm |
Reference product: a 15A American standard socket converter
Executive standard | Clearance between different live parts | Clearance between the live part and the ground wire | Clearance between the fuse soldering spots | Clearance between the relay contact and the cord |
---|---|---|---|---|
UL 60730-1 | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm |
Reference product: a 10A wall switch with a USB port
Executive standard | Clearance between different live parts | Clearance between the live part and the accessible insulating surface | Clearance between the live part and the ground wire | Clearance between the fuse soldering spots | Clearance between isolated circuits |
---|---|---|---|---|---|
GB/T2099.1 | 3 mm | 3 mm | 3 mm | 2.5 mm | 5.0 mm |
Reference product: a 16A wall switch
Executive standard | Clearance between different live parts | Clearance between the live part and the ground wire | Clearance between the live part and the accessible insulating surface |
---|---|---|---|
GB/T2099.3 | 3 mm | 3 mm | 3 mm |
Reference product: appliance switch
Executive standard | Pollution level | Clearance between different live parts | Clearance between the live part and the ground wire | Clearance between the live part and the accessible insulating surface |
---|---|---|---|---|
GB/T15092.1 | 2 | 2.5 mm | 2.5 mm | 2.5 mm |
Reference product: a 15A American standard socket converter
Executive standard | Clearance between different live parts | Clearance between the live part and the ground wire | Clearance between the fuse soldering spots | Clearance between the relay contact and the cord |
---|---|---|---|---|
UL 60730-1 | 1.5 mm | 1.5 mm | 0.5 mm | 0.5 mm |
Reference product: a 10A wall switch with a USB port
Executive standard | Test voltage | Duration | Insulation resistance |
---|---|---|---|
GB/T2099.1 | DC 500V | 1 min | ≥5 MΩ |
Reference product: a 16A wall switch
Executive standard | Test voltage | Duration | Insulation resistance (between L&N and the ground wire) | Insulation resistance (between L&N and the shell) |
---|---|---|---|---|
GB/T2099.3 | DC 500V | 1 min | ≥5 MΩ | ≥5 MΩ |
Reference product: appliance switch
Executive standard | Test voltage | Duration | Insulation resistance (between L&N and the ground wire) | Insulation resistance (between L&N and the shell) |
---|---|---|---|---|
GB/T15092.1 | DC 500V | 1 min | ≥2 MΩ | ≥2 MΩ |
Reference product: a 15A American standard socket converter
Executive standard | Test voltage | Duration | Insulation resistance (between L&N and the ground wire) | Insulation resistance (between L&N and the shell) |
---|---|---|---|---|
UL 60730-1 | DC 500V | 1 min | ≥2 MΩ | ≥7 MΩ |
Executive standard | Test voltage | Duration | Insulation resistance (between L&N and the ground wire) | Insulation resistance (between L&N and the shell) |
---|---|---|---|---|
UL 498A | DC 500V | 1 min | ≥100 MΩ | ≥100 MΩ |
During the test, no flashover or breakdown should occur.
Reference product: a 10A wall switch with a USB port
Executive standard | Test voltage | Duration | Frequency |
---|---|---|---|
GB/T2099.1 | AC 2000V | 1 min | 50 Hz |
Executive standard | Between L and N (fuse disconnected) | L&N and accessible output | L&N and accessible shell |
---|---|---|---|
GB4943.1-2011 | AC 1500V | AC 3000V | AC 3000V |
Reference product: a 16A wall switch
Executive standard | Duration | Frequency | Test voltage (between L&N and the ground wire) | Test voltage (between L&N and the shell) |
---|---|---|---|---|
GB/T2099.3 | 1 min | 50 Hz | 1200V | 2000V |
Reference product: appliance switch
Executive standard | Duration | Frequency | Test voltage (between L&N and the ground wire) | Test voltage (between L&N and the shell) | Test voltage (between relay contacts) |
---|---|---|---|---|---|
GB/T15092.1 | 10s | 50 Hz | 1500V | 1500V | 500V |
Reference product: a 15A American standard socket converter
Executive standard | Duration | Frequency | Test voltage (between L&N and the ground wire) | Test voltage (between L&N and the shell) |
---|---|---|---|---|
UL 60730-1 | 1 min | 60 Hz | 1200V+U | 2400V+ (2*U) |
Note: U is the working voltage.
Reference product: a 15A American standard socket converter
Executive standard | Open circuit | Short circuit | Differential mode | Common mode |
---|---|---|---|---|
UL 60730-1 | 1.2/50µs | 8/20µs | 1 kV | 2 kV |
Reference product: a 15A American standard socket converter
Executive standard | Frequency | Pulse duration Td | Rise time Tr | Voltage |
---|---|---|---|---|
UL 60730-1 | 5 kHz | 15 ms | 300 ms | 1 kV |
Both the Australian socket converter and the German GS standard require L and N to be disconnected at the same time, which can be realized by a two-way on-off relay or two relays (two relays need to be on and off at the same time).
First, you need to find out the point where the temperature rise exceeds the standard, and act accordingly.
Is this page helpful?
YesFeedbackIs this page helpful?
YesFeedback