ZT5 Module Datasheet

Last Updated on : 2024-08-30 09:43:30download

ZT5 is a Zigbee module that Tuya has developed. It consists of a highly integrated RF processing chip (Z2) and a few peripherals. ZT5 is embedded with a low-power 32-bit CPU, 1024-KB flash memory, 64-KB RAM, and rich peripherals.

Overview

Based on ZT5, you can develop embedded Zigbee products as required.

Features

  • Embedded with a low-power 32-bit CPU and ARM Cortex-M33 processor
  • The clock rate: 48 MHz
  • Wide operating voltage: 1.8 to 3.6 V
  • Peripherals: 6 GPIOs, 1 UART, and 1 ADC
  • Zigbee connectivity
    • Support 802.15.4 MAC/PHY
    • Working channels 11 to 26 @2.400 to 2.483 GHz, air interface rate: 250 Kbps
    • Up to +10dBm output power
    • Built-in onboard PCB antenna
    • Onboard PCB antenna with a gain of 2.8 dBi
    • Operating temperature: -40℃ to 85℃
    • Support hardware encryption and AES 128

Applications

  • Intelligent building
  • Smart household and home appliances
  • Smart socket and light
  • Industrial wireless control
  • Baby monitor
  • Intelligent bus

Module interfaces

Dimensions and package

ZT5 has two rows of pins with a spacing of 2±0.1 mm, 14 pins in total.

The ZT5 dimensions are 14.8±0.35mm (W) x 20.4±0.35mm (L) x 2.0±0.15mm (H)

The dimensions of ZT5 are as follows:

ZT5 Module Datasheet
ZT5 Module Datasheet

Pin definition

ZT5 Module Datasheet

Pin number Symbol I/O type Function
1 B4 I/O Support hardware PWM and correspond to B4 (Pin 14) on the internal IC
2 D2 I/O Support hardware PWM and correspond to D2 (Pin 31) on the internal IC
3 C2 I/O Uart_TXD. It can also be used as GPIO, and correspond to C2 (Pin 22) on the internal IC
4 C3 I/O Uart_RXD. It can also be used as GPIO, and correspond to C3 (Pin 23) on the internal IC
5 VCC P Power supply pin of the module (The typical power supply voltage: 3.3V
6 C4 I/O ADC pin, which corresponds to C4 (Pin 24) on the internal IC
7 GND P Power supply reference ground
0 SWS I/O Burning pin, which corresponds to SWS (Pin 5) on the internal IC
00 B5 I/O Support hardware PWM and correspond to B5 (Pin 15) on the internal IC
8 B7 I/O Uart_RXD, which corresponds to B7 (Pin 17) on the internal IC
9 RST I The enabling pin and the EN pin are connected together and a pull-up resistor is connected to them.
10 VCC P Power supply pin of the module (The typical power supply voltage: 3.3V)
11 B1 I/O Uart_TXD.which corresponds to B1 (Pin 6) of the IC
12 GND P Power supply reference ground

Note: P indicates a power supply pin and I/O indicates an input/output pin.

Electrical parameters

Absolute electrical parameters

Parameter Description Minimum value Maximum value Unit
Ta Operating temperature -40 85
VBAT Power supply voltage 1.9 3.6 V
ESD voltage (human body model) TAMB-25℃ - 2 KV
ESD voltage (machine model) TAMB-25℃ - 0.5 KV

Normal working conditions

Parameter Description Minimum Value Typical Value Maximum Value Unit
Ta Operating temperature -40 - 85
VCC Operating voltage 1.9 3.3 3.6 V
VIL I/O low level input - - VDD*0.3 V
VIH I/O high level input VDD*0.7 - - V
VOL I/O low level output - - VDD*0.2 V
VOH I/O high level output VDD*0.8 - - V

TX and RX power consumption

Working status Mode Rate Transmit power/receive Average value Peak value (Typical value) Unit
Transmit - 250 Kbps +0 dBm 4.4 29 mA
Transmit - 250 Kbps +10 dBm 9.1 44 mA
Receive - 250 Kbps Constantly receive 6.6 10.2 mA

Operating current

Working mode Working status, Ta = 25°C Average value Maximum value (Typical value) Unit
Quick network connection state The module is in the fast network connection state 9.15 9.49 mA
Connected The module is connected to the network 8.95 9.15 mA
Deep sleep mode Deep sleep mode, reserve 32-KB SRAM 2.8 - μA

RF parameters

Basic RF features

Parameter Description
Working frequency 2.405 to 2.480 GHz
Zigbee standard IEEE 802.15.4
Data transmission rate 250 Kbps
Antenna type PCB antenna with a gain of 2.8 dBi

TX performance

TX performance

Parameter Minimum value Typical value Maximum value Unit
Maximum output power (250Kbps) - 10 - dBm
Minimum output power (250Kbps) - -25 - dBm
Output power adjustment stepping - 0.5 1 dBm
Output spectrum adjacent channel suppression - -31 - dBc
Frequency error -10 - 10 ppm

RX performance

RX sensitivity

Parameter Minimum value Typical value Maximum value Unit
PER<8%, RX sensitivity (250 Kbps) -99 -99 -99 dBm

Module power-on timing requirements

ZT5 Module Datasheet
ZT5 Module Datasheet

The Z2 chip has requirements on the power-on sequence. During the power-on process, the system starts when the RST pin reaches 1.62V. At this time, the VCC needs to reach more than 1.8V within 10ms. Because the RST pin has the RC link, the VCC of the bare module is much more than 1.8V when the RST reaches 1.62V.
In some cases that the large capacitance in the power driver connected to the Z2 chip module charges or discharges, if the module voltage is not fully discharged below 0.6V, the module will probably crash when it is restarted. It is required that the power supply pin VCC_3.3V of the module needs to be connected with a dummy load of 1K to release power quickly. You can refer to the following figure which shows parts of power-driven links.

ZT5 Module Datasheet

Antenna information

Antenna type

ZT5 only uses the onboard PCB antenna.

Antenna interference reduction

To ensure the optimal Zigbee performance when the Zigbee module uses an onboard PCB antenna, it is recommended that the antenna be at least 15 mm away from other metal parts.

To prevent an adverse impact on the antenna radiation performance, avoid copper or traces along the antenna area on the PCB.

ZT5 Module Datasheet

Packaging information and production instructions

Mechanical dimensions

The PCB dimensions are 24±0.35mm (L) x 16±0.35mm (W) x 0.8±0.1mm (H)
ZT5 Module Datasheet

Side view

ZT5 Module Datasheet

The schematic diagram of footprint

ZT5 Module Datasheet

PCB footprint diagram-SMT

ZT5 Module Datasheet

The area indicated as keep-out in the diagram above does not require tinning and should not have any traces routed through it.

Production instructions

  1. The Tuya SMT module should be mounted by the SMT device. After being unpacked, it should be soldered within 24 hours. Otherwise, it should be put into the drying cupboard where the RH is not greater than 10%; or it needs to be packaged under vacuum again and the exposure time needs to be recorded (the total exposure time cannot exceed 168 hours).

    • SMT devices:
      • Mounter
      • SPI
      • Reflow soldering machine
      • Thermal profiler
      • Automated optical inspection (AOI) equipment
    • Baking devices:
      • Cabinet oven
      • Anti-electrostatic and heat-resistant trays
      • Anti-electrostatic and heat-resistant gloves
  2. Storage conditions for a delivered module:

    • The moisture-proof bag must be placed in an environment where the temperature is below 40°C and the relative humidity is lower than 90%.

    • The shelf life of a dry-packaged product is 12 months from the date when the product is packaged and sealed.

    • There is a humidity indicator card (HIC) in the packaging bag.

      ZT5 Module Datasheet

  3. The module needs to be baked in the following cases:

    • The packaging bag is damaged before unpacking.
    • There is no HIC in the packaging bag.
    • After unpacking, circles of 10% and above on the HIC become pink.
    • The total exposure time has lasted for over 168 hours since unpacking.
    • More than 12 months have passed since the sealing of the bag.
  4. Baking settings:

    • Temperature: 40°C and ≤ 5% RH for reel package and 125°C and ≤5% RH for tray package (please use the heat-resistant tray rather than a plastic container)
    • Time: 168 hours for reel package and 12 hours for tray package
    • Alarm temperature: 50°C for reel package and 135°C for tray package
    • Production-ready temperature after natural cooling: < 36°C
    • Re-baking situation: If a module remains unused for over 168 hours after being baked, it needs to be baked again.
    • If a batch of modules is not baked within 168 hours, do not use the wave soldering to solder them. Because these modules are Level-3 moisture-sensitive devices, they are very likely to get damp when exposed beyond the allowable time. In this case, if they are soldered at high temperatures, it may result in device failure or poor soldering.
  5. In the whole production process, take electrostatic discharge (ESD) protective measures.

  6. To guarantee the passing rate, it is recommended that you use the SPI and AOI to monitor the quality of solder paste printing and mounting.

Recommended oven temperature curve

Set oven temperatures according to the following temperature curve of reflow soldering. The peak temperature is 245°C.

ZT5 Module Datasheet

  • A: Temperature axis

  • B: Time axis

  • C: Liquidus temperature: 217 to 220°C

  • D: Ramp-up slope: 1 to 3°C/s

  • E: Duration of constant temperature: 60 to 120s; the range of constant temperature: 150 to 200°C

  • F: Duration above the liquidus: 50 to 70s

  • G: Peak temperature: 235 to 245°C

  • H: Ramp-down slope: 1 to 4°C/s

    Note: The above curve is just an example of the solder paste SAC305. For more details about other solder pastes, please refer to Recommended oven temperature curve in the solder paste specifications.

Storage conditions

ZT5 Module Datasheet

MOQ and packaging information

Product model MOQ (pcs) Shipping packaging method The number of modules per reel The number of reels per carton
ZT5 3600 Tape reel 900 4

Appendix: Statement

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this device.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This device has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses, and can radiate radio frequency energy and, if not installed and used following the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the device and receiver.
  • Connect the device into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Radiation Exposure Statement

This device complies with FCC radiation exposure limits set forth for an uncontrolled rolled environment. This device should be installed and operated with a minimum distance of 20cm between the radiator and your body.

Important Note

This radio module must not be installed to co-locate and operating simultaneously with other radios in the host system except following FCC multi-transmitter product procedures. Additional testing and device authorization may be required to operate simultaneously with other radios.

The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end-user.

The host product manufacturer is responsible for compliance with any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. The final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed.

The end-user manual shall include all required regulatory information/warnings as shown in this manual, including “This product must be installed and operated with a minimum distance of 20 cm between the radiator and user body”.

This device has got an FCC ID: 2ANDL-ZT5. The end product must be labeled in a visible area with the following: “Contains Transmitter Module FCC ID: 2ANDL-ZT5”.

This device is intended only for OEM integrators under the following conditions:
The antenna must be installed such that 20cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna.

As long as the 2 conditions above are met, further transmitter tests will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed.

Declaration of Conformity European Notice

ZT5 Module Datasheet

Hereby, Hangzhou Tuya Information Technology Co., Ltd declares that this module product is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU,2011/65/EU. A copy of the Declaration of conformity can be found at https://www.tuya.com.

ZT5 Module Datasheet

This product must not be disposed of as normal household waste, in accordance with the EU directive for waste electrical and electronic equipment (WEEE-2012/19/EU). Instead, it should be disposed of by returning it to the point of sale, or to a municipal recycling collection point.

The device could be used with a separation distance of 20cm to the human body.